Hazard Evaluation for the Saltwell Chempump and a Saltwell Centrifugal Pump Design using Service Water for Lubrication and Cooling
This report documents results of a preliminary hazard analysis (PHA) covering the existing Crane Chempump and the new salt well pumping design. Three hazardous conditions were identified for the Chempump and ten hazardous conditions were identified for the new salt well pump design. This report also presents the results of the control decision/allocation process. A backflow preventer and associated limiting condition for operation were assigned to one hazardous condition with the new design.
- Research Organization:
- CH2M Hill Hanford Group, Inc., Richland, WA (United States)
- Sponsoring Organization:
- USDOE Office of Environmental Management (EM) (US)
- DOE Contract Number:
- AC27-99RL14047
- OSTI ID:
- 805639
- Report Number(s):
- RPP-6954, Rev.1; ECN-664027; TRN: US0301188
- Resource Relation:
- Other Information: PBD: 16 Nov 2000
- Country of Publication:
- United States
- Language:
- English
Similar Records
Hazard Evaluation for a Salt Well Centrifugal Pump Design Using Service Water for Lubrication and Cooling
Evaluation of Failed Crane Chempumps Used During Salt Well Pumping
Replacement Saltwell Pumping System Document Bibliography