skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Data Report for Catch Tank Vapor Sampling

Abstract

CH2M HILL Hanford Group, Inc. (CHG) is responsible for developing and maintaining the authorization basis for River Protection Project (RPP) facilities and operations. This responsibility includes closure of the Flammable Gas Unreviewed Safety Question (USQ) for waste tank ancillary equipment such as catch tanks, double-contained receiver tanks, 244-AR and 244-CR vaults, 242-S and 242-T Evaporators, and inactive miscellaneous underground storage tanks. To support closure of the Flammable Gas USQ for catch tanks, an analysis of the flammable gas hazard was performed. This document provides a summary of flammable gas data obtained from RPP active catch tanks in FY 2000. Flammable gas level measurements for each catch tank (other than 241-AX-152) are discussed on a tank-by-tank basis in Section 3.0. Conclusions based on the data are provided in Section 4.0. This section also includes recommendations that would be useful when conducting vapor sampling for other miscellaneous tanks (e.g., inactive miscellaneous underground storage tanks).

Authors:
Publication Date:
Research Org.:
CH2M Hill Hanford Group, Inc., Richland, WA (United States)
Sponsoring Org.:
USDOE Office of Environmental Management (EM) (US)
OSTI Identifier:
804785
Report Number(s):
RPP-7022, Rev.0
EDT-630493; TRN: US0301125
DOE Contract Number:  
AC27-99RL14047
Resource Type:
Technical Report
Resource Relation:
Other Information: PBD: 28 Sep 2000
Country of Publication:
United States
Language:
English
Subject:
12 MANAGEMENT OF RADIOACTIVE WASTES, AND NON-RADIOACTIVE WASTES FROM NUCLEAR FACILITIES; SAFETY ENGINEERING; SAMPLING; TANKS; STORAGE FACILITIES; FLAMMABILITY; GASES; GAS ANALYSIS; DATA; RADIOACTIVE WASTES

Citation Formats

NGUYEN, D M. Data Report for Catch Tank Vapor Sampling. United States: N. p., 2000. Web. doi:10.2172/804785.
NGUYEN, D M. Data Report for Catch Tank Vapor Sampling. United States. https://doi.org/10.2172/804785
NGUYEN, D M. 2000. "Data Report for Catch Tank Vapor Sampling". United States. https://doi.org/10.2172/804785. https://www.osti.gov/servlets/purl/804785.
@article{osti_804785,
title = {Data Report for Catch Tank Vapor Sampling},
author = {NGUYEN, D M},
abstractNote = {CH2M HILL Hanford Group, Inc. (CHG) is responsible for developing and maintaining the authorization basis for River Protection Project (RPP) facilities and operations. This responsibility includes closure of the Flammable Gas Unreviewed Safety Question (USQ) for waste tank ancillary equipment such as catch tanks, double-contained receiver tanks, 244-AR and 244-CR vaults, 242-S and 242-T Evaporators, and inactive miscellaneous underground storage tanks. To support closure of the Flammable Gas USQ for catch tanks, an analysis of the flammable gas hazard was performed. This document provides a summary of flammable gas data obtained from RPP active catch tanks in FY 2000. Flammable gas level measurements for each catch tank (other than 241-AX-152) are discussed on a tank-by-tank basis in Section 3.0. Conclusions based on the data are provided in Section 4.0. This section also includes recommendations that would be useful when conducting vapor sampling for other miscellaneous tanks (e.g., inactive miscellaneous underground storage tanks).},
doi = {10.2172/804785},
url = {https://www.osti.gov/biblio/804785}, journal = {},
number = ,
volume = ,
place = {United States},
year = {Thu Sep 28 00:00:00 EDT 2000},
month = {Thu Sep 28 00:00:00 EDT 2000}
}