Title: Final results of double-shell tank 241-AZ-101 ultrasonic inspection

Technical Report ·
DOI:https://doi.org/10.2172/797738· OSTI ID:797738

This document presents the results and documentation of the nondestructive ultrasonic examination of tank 241-AZ-101. A tank inspection supplier was retained to provide and use an ultrasonic examination system (equipment, procedures, and inspectors) to scan a limited area of double-shell tank 241-AZ-101 primary tank wall and welds. The inspection found one reportable indication of thinning and no reportable pitting, corrosion, or cracking.

Research Organization:
LMHC (US)
Sponsoring Organization:
ENVIRONMENTAL MANAGEMENT (US)
DOE Contract Number:
AC06-96RL13200
OSTI ID:
797738
Report Number(s):
HNF-4819, Rev.0; TRN: US0204929
Resource Relation:
Other Information: PBD: 23 Aug 1999