Final results of double-shell tank 241-AN-105 ultrasonic inspection
This document presents the results and documentation of the nondestructive ultrasonic examination of tank 241-AN-105. A tank inspection supplier was retained to provide and use an ultrasonic examination system (equipment, procedures, and inspectors) to scan a limited area of double-shell tank 241-AN-105 primary tank wall primary knuckle, and secondary tank bottom. The inspection found some indication of general and local wall thinning with no cracks detected.
- Research Organization:
- LMHC (US)
- Sponsoring Organization:
- ENVIRONMENTAL MANAGEMENT (US)
- DOE Contract Number:
- AC06-96RL13200
- OSTI ID:
- 797735
- Report Number(s):
- HNF-4816, Rev.0; TRN: US0204926
- Resource Relation:
- Other Information: PBD: 23 Aug 1999
- Country of Publication:
- United States
- Language:
- English
Similar Records
Final results of double-shell tank 241-AY-102 ultrasonic inspection
Final results of double-shell tank 241-AN-106 ultrasonic inspection
Final results of double-shell tank 241-AZ-101 ultrasonic inspection
Technical Report
·
Mon Aug 23 00:00:00 EDT 1999
·
OSTI ID:797735
Final results of double-shell tank 241-AN-106 ultrasonic inspection
Technical Report
·
Mon Aug 23 00:00:00 EDT 1999
·
OSTI ID:797735
Final results of double-shell tank 241-AZ-101 ultrasonic inspection
Technical Report
·
Mon Aug 23 00:00:00 EDT 1999
·
OSTI ID:797735