Title: Mass Sensor

Technical Report ·
DOI:https://doi.org/10.2172/773361· OSTI ID:773361

The purpose of this CRADA was to use Honeywell's experience in low temperature cofire ceramics and traditional ceramics to assemble a relatively low-cost, mass-producible miniature mass analyzer. The specific design, given to us by Mass Sensors, LLC, was used to test for helium. The direct benefit for the participant was to have a prototype unit assembled for the purpose of proof of concept and the ability to secure venture capital investors. From that, the company would begin producing their own product for sale. The consumer/taxpayer benefits come from the wide variety of industries that can utilize this technology to improve quality of life. Medical industry can use this technology to improve diagnostic ability; manufacturing industry can use it for improved air, water, and soil monitoring to minimize pollution; and the law enforcement community can use this technology for identification of substances. These are just a few examples of the benefit of this technology. The benefits to DOE were in the area of process improvement for cofire and ceramic materials. From this project we demonstrated nonlinear thickfilm fine lines and spaces that were 5-mil wide with 5-mil spaces; determined height-to diameter-ratios for punched and filled via holes; demonstrated the ability to punch and fill 5-mil microvias; developed and demonstrated the capability to laser cut difficult geometries in 40-mil ceramic; developed and demonstrated coupling LTCC with standard alumina and achieving hermetic seals; developed and demonstrated three-dimensional electronic packaging concepts; and demonstrated printing variable resistors within 1% of the nominal value and within a tightly defined ratio. The capability of this device makes it invaluable for many industries. The device could be used to monitor air samples around manufacturing plants. It also could be used for monitoring automobile exhaust, for doing blood gas analysis, for sampling gases being emitted by volcanoes, for studying activities of insects, and many other things. The ultimate goal was to build two iterations of the mass sensor. However, due to technical difficulties, only one iteration of the device was manufactured. Initial work to optimize the ion source and build a small ion pump was not successful. Consequently, the ion pump was not incorporated into the analyzer design. Mass Sensors, LLC, is still testing the analyzers that were assembled.

Research Organization:
Kansas City Plant, Kansas City, MO (US)
Sponsoring Organization:
US Department of Energy (US)
DOE Contract Number:
AC04-76DP00613
OSTI ID:
773361
Report Number(s):
KCP-613-6363; CRADA-98KCP1070; TRN: AH200109%%5
Resource Relation:
Other Information: PBD: 18 Jan 2001
Country of Publication:
United States
Language:
English