Evaluation of field applications of boric acid in PWR steam generators. Final report
Technical Report
·
OSTI ID:7123115
Secondary system chemistry and steam generator denting progression data for seven pressurized water reactors were reviewed in an attempt to evaluate the effects of boric acid addition on denting. Although laboratory data were conclusive relative to the beneficial effect of boric acid, data from KoRi 1, Indian Point 2, and Indian Point 3, where boric acid was employed for extensive periods, did not allow a similar conclusion to be developed for operating plants.
- Research Organization:
- NWT Corp., San Jose, CA (USA)
- OSTI ID:
- 7123115
- Report Number(s):
- EPRI-NP-3278; ON: TI84920365
- Country of Publication:
- United States
- Language:
- English
Similar Records
Effect of boric acid treatment on the secondary cycle at ANO-2. Final report
Implementation of boric acid in the field - Indian Point Unit 3 plant. Final report
Boric acid inhibition of steam generator materials corrosion
Technical Report
·
Fri Nov 01 00:00:00 EST 1985
·
OSTI ID:7123115
Implementation of boric acid in the field - Indian Point Unit 3 plant. Final report
Technical Report
·
Sun May 01 00:00:00 EDT 1983
·
OSTI ID:7123115
Boric acid inhibition of steam generator materials corrosion
Conference
·
Tue Jan 01 00:00:00 EST 1985
· Trans. Am. Nucl. Soc.; (United States)
·
OSTI ID:7123115
Related Subjects
21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS
PWR TYPE REACTORS
STEAM GENERATORS
CORROSION DENTING
BORIC ACID
WATER CHEMISTRY
BOILERS
CHEMISTRY
DEFORMATION
HYDROGEN COMPOUNDS
INORGANIC ACIDS
REACTORS
VAPOR GENERATORS
WATER COOLED REACTORS
WATER MODERATED REACTORS
210200* - Power Reactors
Nonbreeding
Light-Water Moderated
Nonboiling Water Cooled
PWR TYPE REACTORS
STEAM GENERATORS
CORROSION DENTING
BORIC ACID
WATER CHEMISTRY
BOILERS
CHEMISTRY
DEFORMATION
HYDROGEN COMPOUNDS
INORGANIC ACIDS
REACTORS
VAPOR GENERATORS
WATER COOLED REACTORS
WATER MODERATED REACTORS
210200* - Power Reactors
Nonbreeding
Light-Water Moderated
Nonboiling Water Cooled