Proposed design of SAMUS (small angle muon spectrometer) toroid and its magnetic field calculation
Abstract
Presently the D/null/ detector has three big toroidal magnets; one Central Toroid (CF) and two End Wall Toroids (EF). The EF toroids have central openings 72'' x 72''. Originally, this opening was meant for possible future end-plug calorimeters. Instead we are now designing Small Angle Muon Spectrometer (SAMUS) for the opening. The major component will be built at Serpukhov. The design of the toroid magnets and its magnetic field calculations is being done by exchanging information between Serpukhov and Fermilab. 2 refs., 4 figs., 1 tab.
- Authors:
- Publication Date:
- Research Org.:
- Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States)
- OSTI Identifier:
- 7081926
- Report Number(s):
- FNAL-TM-1537
ON: DE88016747
- DOE Contract Number:
- AC02-76CH03000
- Resource Type:
- Technical Report
- Resource Relation:
- Other Information: Portions of this document are illegible in microfiche products
- Country of Publication:
- United States
- Language:
- English
- Subject:
- 46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY; MAGNETIC FIELD CONFIGURATIONS; TWO-DIMENSIONAL CALCULATIONS; SPECTROMETERS; DESIGN; MAGNETIC FIELDS; MAGNETS; SMALL ANGLE SCATTERING; MEASURING INSTRUMENTS; SCATTERING; 440104* - Radiation Instrumentation- High Energy Physics Instrumentation
Citation Formats
Yamada, R. Proposed design of SAMUS (small angle muon spectrometer) toroid and its magnetic field calculation. United States: N. p., 1988.
Web. doi:10.2172/7081926.
Yamada, R. Proposed design of SAMUS (small angle muon spectrometer) toroid and its magnetic field calculation. United States. https://doi.org/10.2172/7081926
Yamada, R. 1988.
"Proposed design of SAMUS (small angle muon spectrometer) toroid and its magnetic field calculation". United States. https://doi.org/10.2172/7081926. https://www.osti.gov/servlets/purl/7081926.
@article{osti_7081926,
title = {Proposed design of SAMUS (small angle muon spectrometer) toroid and its magnetic field calculation},
author = {Yamada, R},
abstractNote = {Presently the D/null/ detector has three big toroidal magnets; one Central Toroid (CF) and two End Wall Toroids (EF). The EF toroids have central openings 72'' x 72''. Originally, this opening was meant for possible future end-plug calorimeters. Instead we are now designing Small Angle Muon Spectrometer (SAMUS) for the opening. The major component will be built at Serpukhov. The design of the toroid magnets and its magnetic field calculations is being done by exchanging information between Serpukhov and Fermilab. 2 refs., 4 figs., 1 tab.},
doi = {10.2172/7081926},
url = {https://www.osti.gov/biblio/7081926},
journal = {},
number = ,
volume = ,
place = {United States},
year = {Thu Jun 09 00:00:00 EDT 1988},
month = {Thu Jun 09 00:00:00 EDT 1988}
}
Save to My Library
You must Sign In or Create an Account in order to save documents to your library.