Retrofitting sacrificial anodes in the Arabian Gulf
Journal Article
·
· Materials Performance
OSTI ID:691424
Cathodic protection (CP) systems of 15 fixed offshore platforms were analyzed. These steel template structures, off the coast of the United Arab Emirates, are in water depths between 125 and 185 ft (115 and 170 m). A systematic survey program exists to monitor the CP systems including assessment of sacrificial anode depletion, and measurement of anode and platform potentials. These data are used to design new anode retrofits for older structures to extend CP system life. An analysis of field survey measurements, the method used to evaluate new anode needs, and locations for retrofit anodes are described.
- OSTI ID:
- 691424
- Journal Information:
- Materials Performance, Vol. 38, Issue 8; Other Information: PBD: Aug 1999
- Country of Publication:
- United States
- Language:
- English
Similar Records
Experiences in retrofitting sacrificial anodes in offshore Arabian Gulf
The use of cathodic protection current density surveys for optimizing offshore surveys and anode retrofit design
Current density surveys for optimizing offshore anode retrofit design
Conference
·
Thu Dec 31 00:00:00 EST 1998
·
OSTI ID:691424
The use of cathodic protection current density surveys for optimizing offshore surveys and anode retrofit design
Conference
·
Wed Nov 01 00:00:00 EST 1995
·
OSTI ID:691424
+2 more
Current density surveys for optimizing offshore anode retrofit design
Journal Article
·
Mon Apr 01 00:00:00 EST 1996
· Materials Performance
·
OSTI ID:691424
+2 more