Title: Dry hog fuel to improve effiency, cut emissions

Journal Article · · Power; (United States)
OSTI ID:6777391

Various dryers in wood-fired powerplants are described and it is stated that when moisture levels of hog fuel rise above 55%, boilers cannot produce enough heat to sustain combustion. Methods to avoid this problem are suggested and include the burning of a low-moisture fuel in conjunction with the hog fuel and the installation of a dryer to remove some moisture from the fuel before it enter the furnace. It is generally agreed that flue-gas dryers should be considered in the design of hog-fuel-fired steam sytems whenever fuel moisture exceeds about 50%.

OSTI ID:
6777391
Journal Information:
Power; (United States), Journal Name: Power; (United States)
Country of Publication:
United States
Language:
English

Similar Records

Hog fuel drying using vapour recompression
Conference · Thu Dec 01 00:00:00 EST 1983 · Alternative Energy Sources; (United States) · OSTI ID:6777391

Ketchikan Pulp's hog-fuel-boiler energy retrofits
Journal Article · Sun Sep 01 00:00:00 EDT 1991 · Tappi; (United States) · OSTI ID:6777391

Suspension firing of hog fuel, other biomass or peat
Patent · Tue Aug 06 00:00:00 EDT 1985 · OSTI ID:6777391