Title: Thermal and flow analysis of the Fluor Daniel, Inc., Nuclear Material Storage Facility renovation design (initial 30% effort of Title 1)

The computational fluid dynamics code CFX4.2 was used to evaluate steady-state thermal-hydraulic conditions in the Fluor Daniel, Inc., Nuclear Material Storage Facility renovation design (initial 30% of Title 1). Thirteen facility cases were evaluated with varying temperature dependence, drywell-array heat-source magnitude and distribution, location of the inlet tower, and no-flow curtains in the drywell-array vault. Four cases of a detailed model of the inlet-tower top fixture were evaluated to show the effect of the canopy-cruciform fixture design on the air pressure and flow distributions.
Authors:
; ;
Publication Date:
OSTI Identifier:
677007
Report Number(s):
LA-UR--98-1902
ON: DE99000560; TRN: 99:001037
DOE Contract Number:
W-7405-ENG-36
Resource Type:
Technical Report
Resource Relation:
Other Information: PBD: Mar 1998
Research Org:
Los Alamos National Lab., NM (United States)
Sponsoring Org:
USDOE, Washington, DC (United States)
Country of Publication:
United States
Language:
English
Subject:
05 NUCLEAR FUELS; STORAGE FACILITIES; DESIGN; MODIFICATIONS; HEAT TRANSFER; FLOW MODELS; C CODES; PLUTONIUM; AIR FLOW; THERMAL ANALYSIS; TEMPERATURE CONTROL