Title: Tdp studies and tests for C. A. Energia Electrica de Venezuela (enelven) at planta ramon laguna, units RL-17 and RL-10. Volume 3. Unit RL-10 turbine generator condition assessment report and units RL-10 and RL-11 boiler feed pump conditon assessment report. Export trade information

Technical Report ·
OSTI ID:6618161

The study, conducted by Babcock and Wilcox, was funded by the U.S. Trade and Development agency on behalf of Enelven. In order to maximize generated power output and minimize operating costs at Planta Ramon Laguna, tests were done to evaluate the condition of equipment at the plant. In order to identify any damage and determine the operating output of each unit, assessments were done of the furnaces, boilers, generators and boiler feed pumps being used in the plant. The report presents the results of these tests. This is the last of three volumes and it is divided into the following sections: (1) Condition Assessment of Unit RL-10 Turbine-Generator; (2) Condition Assessment of Unit RL-10 and RL-11 Boiler Feed Pumps.

Research Organization:
Babcock and Wilcox Co., Barberton, OH (United States)
OSTI ID:
6618161
Report Number(s):
PB-95-170130/XAB
Resource Relation:
Other Information: This document was provided to NTIS by the U.S. Trade and Development Agency, Rosslyn, VA. See also Volume 2, PB--95-170122
Country of Publication:
United States
Language:
English