skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Preliminary control technology assessment of Mansfield Sanitary, Incorporated, Errysville, Ohio

Technical Report ·
OSTI ID:6542971

A visit was made to the Mansfield Sanitary Facility, Perrysville, Ohio to evaluate control methods in place at the site to protect workers from on the job hazards. This facility used a variety of clays, parting compounds, and color additives to blend, form, dry, fire, package, and ship as ceramic plumbing products. Clays used include feldspar, pearless china clay, and nepheline syenite from various suppliers. Other raw materials included Millwood sand, gum, cultozine-fuchsine, industrial plaster, stain, glaze, magnesium aluminum silicate, talc, feldspar, and zirconium silicate. The company made good use of several ventilation techniques at loading stations, transfer points, automatic assembly lines, and the glazing stations. Parting dust became airborne when applied to the molds and while the mold was being dried. Exhaust-ventilation booths used for the spraying of glaze appeared to be very effective. Several areas in which dust-control methods appeared inadequate were noted. The author recommends that some of the work practices and personal protective equipment used as controls should be examined in an in-depth evaluation and documentation.

Research Organization:
National Inst. for Occupational Safety and Health, Cincinnati, OH (USA)
OSTI ID:
6542971
Report Number(s):
PB-89-129753/XAB; ECTB-110-16A
Country of Publication:
United States
Language:
English