Title: Tornado risk analysis at Savannah River Plant using windspeed damage thresholds and single building strike frequencies

Conference ·
OSTI ID:6436861

In order to evaluate the safety of existing structures and properly design new structures, an analysis of tornado resistance was conducted on each process building at SRP and other buildings by type. Damage estimates were cataloged for each Fujita class windspeed interval and windspeeds were cataloged as a function of increased levels of damage. The probability, for any structure, of a tornado exceeding each windspeed threshold was calculated using the TORRISK computer code which was developed for calculating the probability of a tornado strike on nuclear power generating plants.