skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Unconventional cyclone separators

Journal Article · · International Chemical Engineering (A Quarterly Journal of Translations from Russia, Eastern Europe and Asia); (United States)
OSTI ID:6432912

Conventional cyclone separators are seldom suitable for dust removal from gases according to present standards. The reason is the presence of secondary currents within the cyclone body, which disturb the process of separation as predicted by elementary cyclone theory. Interference can be avoided by special design of the cyclone, including the geometry of the separation chamber, the position of openings, use of flow guides within the cyclone, the dimension and the geometry of the hopper, bleeding and bypassing of the gas, use of multicyclones, and means for dust agglomeration.

OSTI ID:
6432912
Journal Information:
International Chemical Engineering (A Quarterly Journal of Translations from Russia, Eastern Europe and Asia); (United States), Vol. 33:1; ISSN 0020-6318
Country of Publication:
United States
Language:
English