Radiographic identification of loose bodies in the traumatized hip joint
- Univ. of California at Irvine, Orange
Acrylic spacers and cubes of cortical bone of known dimensions were placed in predetermined locations in cadaver hip joints, which were then studied with plain radiography and linear, hypocycloidal, and computed tomography (CT). Joint space widening was not measurable on plain radiographs of the pelvis when 2-mm spacers were placed anywhere within the hip joint. When 4-mm spacers were used, widening measured 2 mm in the axis of measurement corresponding to the location of the spacer. Linear tomography did not permit identification of the 2-mm cubes; however, hypocycloidal tomography and CT consistently showed them anywhere within the hip joint. Radiation dose and clinical recommendations are discussed.