Title: Results from transient tests and spherical valve closure tests, Raccoon Mountain Pumped-Storage Plant

Technical Report ·
OSTI ID:6329967

Tests were conducted at the Raccoon Mountain Pumped-Storage Plant to obtain data on hydraulic system characteristics during transient-state operation, to compare measured values for system pressures and surge levels with design values, to provide information for review of hydaulic transient computations, and to provide confirmation that the spherical valves are capable of shutting off plant flow under emergency conditions. The tests included single-unit load rejection, single-unit pump power loss, multi-unit emergency shutdown from generating, multi-unit emergency shutdown from pumping, and spherical valve closure.

Research Organization:
Tennessee Valley Authority, Norris (USA)
OSTI ID:
6329967
Report Number(s):
TVA/PUB-84/82; ON: DE85900240
Resource Relation:
Other Information: Portions are illegible in microfiche products
Country of Publication:
United States
Language:
English