Title: A case history on an innovative solution for VOC and air toxics control designed for a medical prosthetic manufacturer of silicon breast implants

Conference ·
OSTI ID:625659
 [1]
  1. Environmental Consulting Services, Santa Barbara, CA (United States)

The case history presented here is based on the selection, design, installation, testing in, and continuous operation of a recuperative type thermal oxidation system with a built on heat exchanger unit (with a thermal efficiency of 85%) and ancillary ventilation/exhaust collection system designed for McGhan Medical Corporation (McGhan), a medical prosthetic manufacturer of silicon breast implants, located in Santa Barbara, California. There is now available three (3) consecutive years of emissions source test data which verify the achievement of the overall equipment VOC destruction removal efficiency (DRE) initially projected at 98.5% or 10 ppmv.

OSTI ID:
625659
Report Number(s):
CONF-9702113-; TRN: 98:002184-0034
Resource Relation:
Conference: Specialty conference on emerging solutions to VOC and air toxics control, San Diego, CA (United States), 26-28 Feb 1997; Other Information: PBD: 1997; Related Information: Is Part Of Emerging solutions to VOC & air toxics control; PB: 525 p.
Country of Publication:
United States
Language:
English

Similar Records

Fluidized-bed catalytic oxidation/caustic scrubbing for control of halogenated VOC emissions
Conference · Sun Dec 31 00:00:00 EST 1995 · OSTI ID:625659

The use of a prosthetic tissue expander to displace bowel from a brachytherapy implant site
Journal Article · Sat Dec 01 00:00:00 EST 1990 · International Journal of Radiation Oncology, Biology and Physics; (USA) · OSTI ID:625659

Case history: Effectively operating an RTO with batch VOC spikes
Conference · Thu Jul 01 00:00:00 EDT 1999 · OSTI ID:625659