Title: Testing of gloves for permeability to UV-curable acrylate coatings

Abstract

The handling of UV-curable acrylate formulations used in the coating of optical fiber requires protective measures to prevent contact dermatitis and/or allergic dermatitis. To characterize the permeability of various glove materials to a UV-curable acrylate coating, a study was undertaken using a modification of a standard ASTM permeability test, which demonstrated that nitrile rubber gloves provided the best protection of those glove materials tested.

Authors:
; ;
Publication Date:
Research Org.:
ATandT Network Systems, Norcross, GA
OSTI Identifier:
6250072
Resource Type:
Journal Article
Journal Name:
Am. Ind. Hyg. Assoc. J.; (United States)
Additional Journal Information:
Journal Volume: 48:7
Country of Publication:
United States
Language:
English
Subject:
42 ENGINEERING; GLOVES; PERMEABILITY; ACRYLATES; DERMATITIS; LATEX; NEOPRENE; NITRILES; PERFORMANCE TESTING; PROTECTIVE CLOTHING; CARBOXYLIC ACID SALTS; CLOTHING; DISEASES; ELASTOMERS; ORGANIC CHLORINE COMPOUNDS; ORGANIC COMPOUNDS; ORGANIC HALOGEN COMPOUNDS; ORGANIC NITROGEN COMPOUNDS; ORGANIC POLYMERS; POLYMERS; RUBBERS; SKIN DISEASES; TESTING; 420202* - Engineering- Protective Structures & Equipment

Citation Formats

Huggins, R, Levy, N, and Pruitt, P M. Testing of gloves for permeability to UV-curable acrylate coatings. United States: N. p., 1987. Web. doi:10.1080/15298668791385363.
Huggins, R, Levy, N, & Pruitt, P M. Testing of gloves for permeability to UV-curable acrylate coatings. United States. https://doi.org/10.1080/15298668791385363
Huggins, R, Levy, N, and Pruitt, P M. 1987. "Testing of gloves for permeability to UV-curable acrylate coatings". United States. https://doi.org/10.1080/15298668791385363.
@article{osti_6250072,
title = {Testing of gloves for permeability to UV-curable acrylate coatings},
author = {Huggins, R and Levy, N and Pruitt, P M},
abstractNote = {The handling of UV-curable acrylate formulations used in the coating of optical fiber requires protective measures to prevent contact dermatitis and/or allergic dermatitis. To characterize the permeability of various glove materials to a UV-curable acrylate coating, a study was undertaken using a modification of a standard ASTM permeability test, which demonstrated that nitrile rubber gloves provided the best protection of those glove materials tested.},
doi = {10.1080/15298668791385363},
url = {https://www.osti.gov/biblio/6250072}, journal = {Am. Ind. Hyg. Assoc. J.; (United States)},
number = ,
volume = 48:7,
place = {United States},
year = {Wed Jul 01 00:00:00 EDT 1987},
month = {Wed Jul 01 00:00:00 EDT 1987}
}