Title: Study of SSIN (single-stage interconnection networks) parallel-processing interconnection networks. Final report, 1 October 1987-30 September 1988

Abstract

The increase in dynamic average path length (DAPL) with network size is moderate while it is significantly less than log(2)N, the number of stages needed in a MIN. The best performance in the case of no fault and single fault, is obtained for the modified Omega and the Zeta SSINs.

Authors:
Publication Date:
Research Org.:
North Carolina State Univ., Raleigh (USA). Dept. of Electrical and Computer Engineering
OSTI Identifier:
6211096
Report Number(s):
AD-A-202023/8/XAB
Resource Type:
Technical Report
Country of Publication:
United States
Language:
English
Subject:
99 GENERAL AND MISCELLANEOUS//MATHEMATICS, COMPUTING, AND INFORMATION SCIENCE; COMPUTER NETWORKS; PARALLEL PROCESSING; ELECTRONIC CIRCUITS; FAULT TREE ANALYSIS; LENGTH; PROGRESS REPORT; DIMENSIONS; DOCUMENT TYPES; PROGRAMMING; SYSTEM FAILURE ANALYSIS; SYSTEMS ANALYSIS; 990210* - Supercomputers- (1987-1989)

Citation Formats

Agrawal, D P. Study of SSIN (single-stage interconnection networks) parallel-processing interconnection networks. Final report, 1 October 1987-30 September 1988. United States: N. p., 1988. Web.
Agrawal, D P. Study of SSIN (single-stage interconnection networks) parallel-processing interconnection networks. Final report, 1 October 1987-30 September 1988. United States.
Agrawal, D P. 1988. "Study of SSIN (single-stage interconnection networks) parallel-processing interconnection networks. Final report, 1 October 1987-30 September 1988". United States.
@article{osti_6211096,
title = {Study of SSIN (single-stage interconnection networks) parallel-processing interconnection networks. Final report, 1 October 1987-30 September 1988},
author = {Agrawal, D P},
abstractNote = {The increase in dynamic average path length (DAPL) with network size is moderate while it is significantly less than log(2)N, the number of stages needed in a MIN. The best performance in the case of no fault and single fault, is obtained for the modified Omega and the Zeta SSINs.},
doi = {},
url = {https://www.osti.gov/biblio/6211096}, journal = {},
number = ,
volume = ,
place = {United States},
year = {Mon Oct 31 00:00:00 EST 1988},
month = {Mon Oct 31 00:00:00 EST 1988}
}

Technical Report:
Other availability
Please see Document Availability for additional information on obtaining the full-text document. Library patrons may search WorldCat to identify libraries that may hold this item. Keep in mind that many technical reports are not cataloged in WorldCat.

Save / Share: