Title: Cost and performance of Group 2 boiler NOx controls

Conference ·
OSTI ID:617879
;  [1];  [2]
  1. Bechtel Power corp., Gaithersburg, MD (United States)
  2. and others

This paper presents the results of a study conducted to assist EPA in developing the Phase II NO{sub x} rule under Title IV of the Clean Air Act Amendment of 1990 (the Act). The specific purpose of this study was to assess the performance and capital and total levelized costs of NO{sub x} controls pertinent to Group 2 boilers. Group 2 boilers are all coal-fired boilers that are not dry-bottom wall-fired and tangentially fired and include cell burner-fired, cyclone-fired, wet-bottom, vertically fired, stoker-fired, and fluidized-bed boilers.

OSTI ID:
617879
Report Number(s):
CONF-970145-; TRN: 98:002057-0048
Resource Relation:
Conference: 2. joint conference on acid rain and electric utilities, Scottsdale, AZ (United States), 20-22 Jan 1997; Other Information: PBD: 1997; Related Information: Is Part Of Acid rain & electric utilities II; PB: 1047 p.
Country of Publication:
United States
Language: