skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Measurement of suction and discharge pressure pulsations in waterflood facilities

Conference · · Soc. Pet. Eng. AIME, Pap.; (United States)
OSTI ID:5930684

Recent mechanical problems with reciprocating water injection pumps prompted a study of suction and discharge pressure conditions in the Red River Bull Bayou Unit, Red River Parish, La. Frequent failures in plunger pump components and discharge lines were occurring at several injection sites within the unit. Electronic surveillance equipment consisting of an oscilloscope and pressure transducers was utilized to locate and identify large suction and discharge pressure pulses. The severity of these pulses could not be identified with standard pressure gages. The data obtained with the electronic equipment indicated that cavitation was occurring on the suction side of the pumps due to insufficient net positive suction head. The large pressure pulsations caused by this cavitation problem were carried through the pump and amplified on the discharge side. Changes in the suction and discharge piping design eliminated cavitation and effectively reduced the peak pressure pulses.

OSTI ID:
5930684
Report Number(s):
CONF-8310121-
Journal Information:
Soc. Pet. Eng. AIME, Pap.; (United States), Vol. SPE-12194; Conference: SPE annual technical conference, San Francisco, CA, USA, 5 Oct 1983
Country of Publication:
United States
Language:
English