Title: Respirable dust from lignite coal in the Victorian power industry

Journal Article · · Am. Ind. Hyg. Assoc. J.; (United States)

The results of a 12-month programme of static sampling for respirable dust at various work sites of the Victorian power industry are presented. Lignite is the major source of dust. The data appear to be nearly lognormal in distribution and are similar in magnitude to levels reported from North American surface mines and surface work sites. Average 8-hour, time-weighted-average dust concentrations of 0.3 mg/m/sup 3/ were found in open areas. In enclosed coal-handling areas, average concentrations of 0.7 mg/m/sup 3/ were found.

OSTI ID:
5819920
Journal Information:
Am. Ind. Hyg. Assoc. J.; (United States), Vol. 44:4
Country of Publication:
United States
Language:
English