Electro-optical system for the high speed reconstruction of computed tomography images
An electro-optical system for the high-speed reconstruction of computed tomography (CT) images has been built and studied. The system is capable of reconstructing high-contrast and high-resolution images at video rate (30 images per second), which is more than two orders of magnitude faster than the reconstruction rate achieved by special purpose digital computers used in commercial CT systems. The filtered back-projection algorithm which was implemented in the reconstruction system requires the filtering of all projections with a prescribed filter function. A space-integrating acousto-optical convolver, a surface acoustic wave filter and a digital finite-impulse response filter were used for this purpose and their performances were compared. The second part of the reconstruction, the back projection of the filtered projections, is computationally very expensive. An optical back projector has been built which maps the filtered projections onto the two-dimensional image space using an anamorphic lens system and a prism image rotator. The reconstructed image is viewed by a video camera, routed through a real-time image-enhancement system, and displayed on a TV monitor. The system reconstructs parallel-beam projection data, and in a modified version, is also capable of reconstructing fan-beam projection data. This extension is important since the latter are the kind of projection data actually acquired in high-speed X-ray CT scanners. The reconstruction system was tested by reconstructing precomputed projection data of phantom images. These were stored in a special purpose projection memory and transmitted to the reconstruction system as an electronic signal. In this way, a projection measurement system that acquires projections sequentially was simulated.
- Research Organization:
- Yale Univ., New Haven, CT (USA)
- OSTI ID:
- 5734326
- Resource Relation:
- Other Information: Thesis (Ph. D.)
- Country of Publication:
- United States
- Language:
- English
Similar Records
Iterative metal artifact reduction for x-ray computed tomography using unmatched projector/backprojector pairs
MO-G-17A-07: Improved Image Quality in Brain F-18 FDG PET Using Penalized-Likelihood Image Reconstruction Via a Generalized Preconditioned Alternating Projection Algorithm: The First Patient Results
Related Subjects
COMPUTERIZED TOMOGRAPHY
OPTIMIZATION
ALGORITHMS
IMAGE PROCESSING
PHANTOMS
REAL TIME SYSTEMS
X RADIATION
DIAGNOSTIC TECHNIQUES
ELECTROMAGNETIC RADIATION
IONIZING RADIATIONS
MATHEMATICAL LOGIC
MOCKUP
PROCESSING
RADIATIONS
STRUCTURAL MODELS
TOMOGRAPHY
550602* - Medicine- External Radiation in Diagnostics- (1980-)