skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Sampling trace-level organic solutes with polymeric tubing. Part 1: Static studies

Journal Article · · Ground Water Monitoring and Remediation

Twenty polymeric tubings were filled with a test solution containing eight organic solutes. The test solutions were monitored for losses, indicating that sorption had occurred, and for signs that leaching of organic constituents had occurred. The tubings tested included seven flexible products and eight fluoropolymers. Among the rigid tubings tested, three fluoropolymers (fluorinated ethylene propylene (FEP), FEP-lined polyethylene, polyvinylidene fluoride) were the least sorptive tubings. However, even these tubings readily sorbed some of the analytes. Among the flexible tubings tested, a fluoroelastomer tubing and a tubing made of a copolymer of vinylidene fluoride and hexafluoropropylene were the least sorptive. Several of the tubings tested leached constituents into the test solution. The polyurethane, polyamide, flexible polyvinyl chloride (PVC), polyester-lined PVC, and silicone-modified thermoplastic elastomer tubings were found to leach the most constituents. The authors were unable to detect any constituents leaching from the polyethylene tubings, the rigid fluoropolymer tubings, and one of the plasticized polypropylene tubings.

Sponsoring Organization:
USDOE
OSTI ID:
556570
Journal Information:
Ground Water Monitoring and Remediation, Vol. 17, Issue 4; Other Information: PBD: Fal 1997
Country of Publication:
United States
Language:
English