Title: Analysis data on samples from the TMI-2 reactor-coolant system and reactor-coolant bleed tank

Technical Report ·
DOI:https://doi.org/10.2172/5330865· OSTI ID:5330865

Two liquid samples from the Three Mile Island Unit 2 (TMI-2) Reactor Coolant System (RCS) and three liquid samples from the three Reactor Coolant Bleed Tanks (RCBT) were taken during the time period March 29, 1979 to August 14, 1980. The samples were analyzed for radionuclide concentrations by two independent laboratories, Exxon Nuclear Idaho Co., Inc. (ENICO) and EG and G Idaho, Inc. at the Idaho National Engineering Laboratory (INEL). The RCS sample taken on March 29, 1979 was also analyzed by Science Applications, Inc. (SAI). This report presents the methods used and the results of these analyes. 14 tables.

Research Organization:
EG and G Idaho, Inc., Idaho Falls, ID (United States)
DOE Contract Number:
AC07-76ID01570
OSTI ID:
5330865
Report Number(s):
GEND-INF-021; ON: DE82016227; TRN: 82-013429
Resource Relation:
Other Information: Portions of document are illegible
Country of Publication:
United States
Language:
English