skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Configuration analysis: an energy and first cost analysis of a large office building

Conference · · Proc. Annu. Meet. - Am. Sect. Int. Sol. Energy Soc.; (United States)
OSTI ID:5058521

In response to the need to minimize energy use in the new Social Security Administration, Northeast Program Service Center (SSA/NEPSC), now under construction in Jamaica, Queens, New York an analysis of building configuration was undertaken. The one million square foot SSA/NEPSC federal office building was originally designed for a competition won by the joint venture firms of The Gruzen Partnership and The Ehrenkrantz Group, architects and planners, and Syska and Hennessy, mechanical and electrical engineers. When completed, the building will have 3600 employees within a 900,000 GSF, eleven story structure that will form the centerpiece of the Jamaica, Queens revitalization plan. Although substantially redesigned from the competition, two important requirements for the final building design remained: low construction cost ($70/SF-1981, New York) and low yearly energy use (45,000 /SF/YR). The strict construction cost limitations necessitated extensive value engineering of the major building systems. including the configuration.

Research Organization:
The Ehrenkrantz Group, New York, New York
OSTI ID:
5058521
Report Number(s):
CONF-830622-
Journal Information:
Proc. Annu. Meet. - Am. Sect. Int. Sol. Energy Soc.; (United States), Vol. 6; Conference: American Solar Energy Society meeting, Minneapolis, MN, USA, 1 Jun 1983
Country of Publication:
United States
Language:
English