Title: Hydrology of the Greater Tongonan Geothermal system, Philippines and its implications to field exploitation

Conference ·
OSTI ID:494424
; ;  [1]
  1. PNOC-Energy Development Corp., Makati City (Philippines); and others

The Greater Tongonan Geothermal Field will be operating a total of 694 MWe by July 1997. The field has produced steam for the 112.5 MWe Tongonan I power plant since June 1983. With massive fluid withdrawal starting July 1996, a pre-commissioning hydrology was constructed to assess its implications to field exploitation. Pressure drawdown centered at well 106 in Mahiao was induced by fluid withdrawal at Tongonan-I production field. This drawdown will be accelerated by major steam withdrawal (734 kg/s) upon commissioning of power plants at Mahiao, Sambaloran and Malitbog sectors. To resolve this concern, fluid injection will be conducted at the periphery of Mahiao to provide recharge of reheated reinjection fluids in the reservoir. At Mahanagdong, the acidic fluid breakthrough will unlikely occur since the acidic zone north of this sector is not hydrologically well-connected to the main neutral-pH reservoir as indicated by pressure profiles.

OSTI ID:
494424
Report Number(s):
CONF-960913-; TRN: 97:002642-0101
Resource Relation:
Conference: Annual meeting of the Geothermal Resources Council, Portland, OR (United States), 29 Sep - 2 Oct 1996; Other Information: PBD: 1996; Related Information: Is Part Of Geothermal development in the Pacific rim. Transactions, Volume 20; PB: 886 p.
Country of Publication:
United States
Language:
English