Title: Localized heat transfer to verticle forced flow two-phase helium

Conference ·
OSTI ID:416636
; ;  [1]
  1. National Magnetic Field Lab., Tallahassee, FL (United States)

Localized heat transfer measurements in vertical two-phase helium are reported. The test loop contains two short heat transfer sections made of 5 mm thick oxygen-free high conductivity (OFHC) copper discs. These test sections were installed in a U-shaped vertical flow loop driven by a single-stroke bellows pump. The surface temperature of each test section is measured with two germanium thermometers placed on different radial positions in each test section. With one test section placed on the downflow side and one on the upflow side of the loop, the effect of flow orientation on heat transfer characteristics in vertical two-phase helium flow is investigated. The study includes the effects of system pressure, mass flow rate, and geometry on the heat transfer coefficient, critical heat flux, and recovery heat flux.

DOE Contract Number:
FG05-92ER40751
OSTI ID:
416636
Report Number(s):
CONF-950722-; TRN: 97:001617
Resource Relation:
Conference: CEC/ICMC `95: cryogenic engineering conference and international cryogenic materials conference, Columbus, OH (United States), 17-21 Jul 1995; Other Information: PBD: 1996; Related Information: Is Part Of Advances in cryogenic engineering. Volume 41, Part A & B; Kittel, P. [ed.]; PB: 2037 p.
Country of Publication:
United States
Language:
English