skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Japanese developments in condenser fouling control. Part III: Characterization of various sponge balls for aluminum brass tubes

Technical Report ·
OSTI ID:414831
; ;  [1]
  1. Kansai Power Co., Fukui (Japan); and others

Four types of sponge balls: normal, granulate, polishing and corundum were evaluated for fouling removal capabilities, polarization resistance residue and cleaning force. The sponge balls under evaluation were removed from Unit 1 of the Mihama Nuclear Power Station. It was found that the granular ball was the best, however its cleaning force decreased rapidly; the 26 mm polishing ball was better than the normal ball, and, the corundum ball must be used with caution. 2 figs.

Research Organization:
Electric Power Research Inst. (EPRI), Palo Alto, CA (United States); Stone and Webster Engineering Corp., Boston, MA (United States)
OSTI ID:
414831
Report Number(s):
EPRI-TR-106781; CONF-960857-; TRN: 96:006225-0020
Resource Relation:
Conference: Condenser technology seminar and conference, Boston, MA (United States), 26-30 Aug 1996; Other Information: PBD: Aug 1996; Related Information: Is Part Of Proceedings: Condenser technology conference; Tsou, J.L.; Mussalli, Y.G. [eds.]; PB: 463 p.
Country of Publication:
United States
Language: