skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: A summary of SNCR applications to two coal-fired wet bottom boilers

Technical Report ·
OSTI ID:269412
; ;  [1]
  1. Carnot, Tustin, CA (United States); and others

In response to NO{sub x} reductions mandated under Title I of the 1990 Clean Air Act Amendments (CAAA), Public Service Electric & Gas and Atlantic Electric of New Jersey evaluated Selective Non-Catalytic Reduction (SNCR) for NO{sub x} control under separate programs at Mercer Station and B.L. England Station, respectively. Mercer Station is comprised of twin 321 MW Foster Wheeler coal-fired wet bottom boilers, with natural gas capability up to 100% load. B.L. England Station has three units, two of which are cyclone boilers of 136 MW and 163 MW. These furnace designs are of particular interest in that nominally 23,000 MW of cyclone boiler capacity and 6,900 MW of wall- or turbo-fired wet bottom boiler capacity will be faced with NO{sub x} reductions to be mandated under Title IV - Phase II for Group II boilers. Both stations evaluated Nalco Fuel Tech`s SNCR system using a portable test skid, with urea as the reducing chemical. The Mercer Unit 2 demonstration was performed with a low sulfur coal (nominally 0.8%), while the B.L. England Unit 1 demonstration utilized a medium sulfur coal (nominally 2.4%), and also re-injects fly ash back into the cyclones for ultimate collection and removal as slag. To address concerns over potential Ljungstrom air heater fouling, due to reactions between ammonia and SO{sub 3} in the air heater, and fly ash salability at Mercer Station, both sites targeted no greater than 5-10 ppmv ammonia emissions at the economizer exit. At Mercer Unit 2, air heater fouling was only experienced during system start-up when the ammonia emissions at the economizer exit were estimated at levels approaching 60 ppmv. B.L. England Unit 1, however, experienced frequent fouling of the air heater. NO{sub x} reductions achieved at both sites ranged between 30%-40% from nominal baseline NO{sub x} levels of 1.1-1.6 lb/MMBtu. Each site is currently undergoing installation of commercial SNCR systems.

Research Organization:
Electric Power Research Inst. (EPRI), Palo Alto, CA (United States)
OSTI ID:
269412
Report Number(s):
EPRI-TR-105978-V4; CONF-9505150-Vol.4; TRN: 96:002976-0001
Resource Relation:
Conference: EPRI/EPA joint symposium on stationary combustion NO/sub x/ control, Kansas City, MO (United States), 16-19 May 1995; Other Information: PBD: Jan 1996; Related Information: Is Part Of Proceedings: EPRI/EPA 1995 joint symposium on stationary combustion NO{sub x} control: Volume 4, Friday, May 19, 1995, Sessions 8A and 8B; PB: 193 p.
Country of Publication:
United States
Language:
English