skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Performance analysis of a PV powered dc motor driving a 3-phase self-excited induction generator

Journal Article · · IEEE Transactions on Energy Conversion
DOI:https://doi.org/10.1109/60.486590· OSTI ID:248037
 [1]
  1. King Saud Univ., Riyadh (Saudi Arabia)

Photovoltaic (PV) powered dc motors driving dedicated loads (e.g. water pumps) are increasingly used in the remote rural areas of many developing countries. The key to their success is simplicity (direct coupling, no dc-ac inversion, no storage batteries, etc.). In this paper a PV powered dc motor is used to drive an isolated three-phase self-excited induction generator (SEIG). It is found that due to the unique torque-speed characteristics of the SEIG, utilization efficiency is close to maximum at all insolation levels with no peak-power tracking. The proposed arrangement is useful as part of an integrated renewable energy system (IRES), which takes advantage of the inherent diversity of wind and insolation in most developing countries to improve power quality. The SEIG is driven by wind turbine, dc motor, or both. Performance of the system under different insolation conditions is analyzed.

OSTI ID:
248037
Report Number(s):
CONF-950727-; ISSN 0885-8969; TRN: IM9628%%137
Journal Information:
IEEE Transactions on Energy Conversion, Vol. 11, Issue 1; Conference: 1995 IEEE Power Engineering Society summer meeting, Portland, OR (United States), 23-27 Jul 1995; Other Information: PBD: Mar 1996
Country of Publication:
United States
Language:
English