A high-current rail-type gas switch with preionization by an additional corona discharge
The characteristics of a high-current rail-type gas switch with preionization of the gas (air) in a spark gap by an additional corona discharge are investigated. The experiments were performed in a voltage range of 10–45 kV using a two-electrode switch consisting of two cylindrical electrodes with a diameter of 22 mm and a length of 100 mm and a set of laterally located corona-discharge needles. The requirements for the position and size of the needles are defined for which a corona discharge is ignited before a breakdown of the main gap and does not change to a sparking form, and the entire length of the rail electrodes is efficiently used. The fulfillment of these requirements ensures stable operation of the switch with a small variation of the pulse breakdown voltage, which is not more than 1% for a fixed voltage-pulse rise time in the range from 150 ns to 3.5 μs. A short delay time of the switch breakdown makes it possible to control the two-electrode switch by an overvoltage pulse of nanosecond duration.
- OSTI ID:
- 22612522
- Journal Information:
- Physics of Atomic Nuclei, Vol. 79, Issue 14; Other Information: Copyright (c) 2016 Pleiades Publishing, Ltd.; Country of input: International Atomic Energy Agency (IAEA); ISSN 1063-7788
- Country of Publication:
- United States
- Language:
- English
Similar Records
Gas spark switches with increased operating life for Marx generator of lightning test complex
Experimental study of atmospheric pressure single-pulse nanosecond discharge in pin-to-pin configuration