skip to main content

Title: Ablation of biological tissues by radiation of strontium vapor laser

A two-stage laser system consisting of a master oscillator and a power amplifier based on sources of self- contained transitions in pairs SrI and SrII has been developed. The radiation spectrum contains 8 laser lines generating in the range of 1 – 6.45 μm, with a generation pulse length of 50 – 150 ns, and pulse energy of ∼ 2.5 mJ. The divergence of the output beam was close to the diffraction and did not exceed 0.5 mrad. The control range of the laser pulse repetition rate varied from 10 to 15 000 Hz. The given laser system has allowed to perform ablation of bone tissue samples without visible thermal damage.
Authors:
;  [1]
  1. National Research Tomsk State University, Lenin ave., 36, 634050, Tomsk (Russian Federation)
Publication Date:
OSTI Identifier:
22496176
Resource Type:
Journal Article
Resource Relation:
Journal Name: AIP Conference Proceedings; Journal Volume: 1688; Journal Issue: 1; Conference: NEWOT'2015: 5. international scientific conference on new operational technologies, Tomsk (Russian Federation), 29-30 Sep 2015; Other Information: (c) 2015 AIP Publishing LLC; Country of input: International Atomic Energy Agency (IAEA)
Country of Publication:
United States
Language:
English
Subject:
71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSICS; 75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND SUPERFLUIDITY; ABLATION; BEAMS; BONE TISSUES; DIFFRACTION; LASER RADIATION; LASERS; LENGTH; OSCILLATORS; POWER AMPLIFIERS; PULSES; STRONTIUM; VAPORS