Double electron capture of {sup 106}Cd in the TGV-2 experiment
- Joint Institute for Nuclear Research, 141980 Dubna, Moscow region (Russian Federation)
- Centre de Spectrométrie nucléaire et de Spectrométrie de Masse, 19495, Orsay (France)
- Institute of Experimental and Applied Physics, CTU in Prague, 128 00 Prague (Czech Republic)
- Laboratoire Souterrain de Modane, 73500 Modane (France)
A new experimental run of searching for EC/EC decay of {sup 106}Cd was performed at the Modane underground laboratory (4800 m w.e.) using the TGV-2 spectrometer and ∼23.2 g {sup 106}Cd with enrichment of 99.57%. The limit on 2νEC/EC decay of {sup 106}Cd - T{sub 1/2}(2νEC/EC) > 3.1×10{sup 20} y, at 90% C.L was obtained from the preliminary calculation of experimental data accumulated for 7018 h of measurement. The limits on the resonance neutrino-less double electron capture decay of {sup 106}Cd were obtained from the measurement of ∼23.2 g of {sup 106}Cd with the low-background HPGe spectrometer OBELIX lasted 395 h - T{sub 1/2}(KL, 2741 keV) > 0.9×10{sup 20} y and T{sub 1/2}(KK, 2718 keV) > 1.4×10{sup 20} y at 90% C.L.
- OSTI ID:
- 22492672
- Journal Information:
- AIP Conference Proceedings, Vol. 1686, Issue 1; Conference: MEDEX'15: Workshop on calculation of double-beta-decay matrix elements, Prague (Czech Republic), 9-12 Jun 2015; Other Information: (c) 2015 AIP Publishing LLC; Country of input: International Atomic Energy Agency (IAEA); ISSN 0094-243X
- Country of Publication:
- United States
- Language:
- English
Similar Records
Investigations of 2β decay of {sup 106}Cd and {sup 58}Ni with HPGe spectrometer OBELIX
Summary of the TGV experiment and future plans