Title: Castellated tiles as the beam-facing components for the diagnostic calorimeter of the negative ion source SPIDER

This paper presents the results of numerical simulations and experimental tests carried out to assess the feasibility and suitability of graphite castellated tiles as beam-facing component in the diagnostic calorimeter of the negative ion source SPIDER (Source for Production of Ions of Deuterium Extracted from Radio frequency plasma). The results indicate that this concept could be a reliable, although less performing, alternative for the present design based on carbon fiber composite tiles, as it provides thermal measurements on the required spatial scale.
Authors:
; ; ; ; ; ; ; ; ;  [1] ;  [1] ;  [2] ;  [1] ;  [2] ;  [3]
  1. Consorzio RFX, Corso Stati Uniti 4, 35127 Padova (Italy)
  2. (Italy)
  3. Università degli Studi di Padova, Via 8 Febbraio 2, I-35122 Padova (Italy)
Publication Date:
OSTI Identifier:
22483032
Resource Type:
Journal Article
Resource Relation:
Journal Name: Review of Scientific Instruments; Journal Volume: 87; Journal Issue: 2; Other Information: (c) 2015 EURATOM; Country of input: International Atomic Energy Agency (IAEA)
Country of Publication:
United States
Language:
English
Subject:
46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY; ANIONS; BEAMS; CALORIMETERS; CARBON FIBERS; COMPUTERIZED SIMULATION; DESIGN; DEUTERIUM; GRAPHITE; PLASMA; RADIOWAVE RADIATION