Title: An advanced negative hydrogen ion source

The results of investigation of emission productivity of negative particles source with cesiated combined discharge are presented. A cylindrical beam of negative hydrogen ions with density about 2 A/cm{sup 2} in low noise mode on source emission aperture is obtained. The total beam current values are up to 200 mA for negative hydrogen ions and up to 1.5 A for all negative particles with high divergence after source. The source has simple design and can produce stable discharge with low level of oscillation.
Authors:
; ;  [1]
  1. Institute of Physics National Academy of Science in Ukraine, Kiev 03028 (Ukraine)
Publication Date:
OSTI Identifier:
22482936
Resource Type:
Journal Article
Resource Relation:
Journal Name: Review of Scientific Instruments; Journal Volume: 87; Journal Issue: 2; Other Information: (c) 2015 AIP Publishing LLC; Country of input: International Atomic Energy Agency (IAEA)
Country of Publication:
United States
Language:
English
Subject:
46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY; APERTURES; BEAM CURRENTS; BEAMS; CYLINDRICAL CONFIGURATION; DENSITY; DESIGN; EMISSION; HYDROGEN IONS; ION SOURCES; NOISE