Title: Percutaneous Endovascular Salvage Techniques for Implanted Venous Access Device Dysfunction

Journal Article · · Cardiovascular and Interventional Radiology
 [1];  [2]; ;
  1. Lausanne University Hospital, Diagnostic and Interventional Radiology Department (Switzerland)
  2. Lausanne University Hospital, Angiology and Diagnostic and Interventional Radiology Departments (Switzerland)

PurposeImplanted venous access devices (IVADs) are often used in patients who require long-term intravenous drug administration. The most common causes of device dysfunction include occlusion by fibrin sheath and/or catheter adherence to the vessel wall. We present percutaneous endovascular salvage techniques to restore function in occluded catheters. The aim of this study was to evaluate the feasibility, safety, and efficacy of these techniques.Methods and MaterialsThrough a femoral or brachial venous access, a snare is used to remove fibrin sheath around the IVAD catheter tip. If device dysfunction is caused by catheter adherences to the vessel wall, a new “mechanical adhesiolysis” maneuver was performed. IVAD salvage procedures performed between 2005 and 2013 were analyzed. Data included clinical background, catheter tip position, success rate, recurrence, and rate of complication.ResultsEighty-eight salvage procedures were performed in 80 patients, mostly women (52.5 %), with a mean age of 54 years. Only a minority (17.5 %) of evaluated catheters were located at an optimal position (i.e., cavoatrial junction ±1 cm). Mechanical adhesiolysis or other additional maneuvers were used in 21 cases (24 %). Overall technical success rate was 93.2 %. Malposition and/or vessel wall adherences were the main cause of technical failure. No complications were noted.ConclusionThese IVAD salvage techniques are safe and efficient. When a catheter is adherent to the vessel wall, mechanical adhesiolysis maneuvers allow catheter mobilization and a greater success rate with no additional risk. In patients who still require long-term use of their IVAD, these procedures can be performed safely to avoid catheter replacement.

OSTI ID:
22469930
Journal Information:
Cardiovascular and Interventional Radiology, Vol. 38, Issue 3; Conference: CIRSE 2015: Cardiovascular and Interventional Radiological Society of Europe congress, Lisbon (Portugal), 26-30 Sep 2015; Other Information: Copyright (c) 2015 Springer Science+Business Media New York and the Cardiovascular and Interventional Radiological Society of Europe (CIRSE); http://www.springer-ny.com; Country of input: International Atomic Energy Agency (IAEA); ISSN 0174-1551
Country of Publication:
United States
Language:
English

Similar Records

Feasibility and Safety of Endovascular Stripping of Totally Implantable Venous Access Devices
Journal Article · Fri Jun 15 00:00:00 EDT 2012 · Cardiovascular and Interventional Radiology · OSTI ID:22469930

Radiological Interventions for Correction of Central Venous Port Catheter Migrations
Journal Article · Sun Jul 15 00:00:00 EDT 2007 · Cardiovascular and Interventional Radiology · OSTI ID:22469930

Venous Port Salvage Utilizing Low Dose tPA
Journal Article · Sun Dec 15 00:00:00 EST 2002 · Cardiovascular and Interventional Radiology · OSTI ID:22469930