skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Sample preparation and biomass determination of SRF model mixture using cryogenic milling and the adapted balance method

Journal Article · · Waste Management

Highlights: • An alternative sample comminution procedure for SRF is tested. • Proof of principle is shown on a SRF model mixture. • The biogenic content of the SRF is analyzed with the adapted balance method. • The novel method combines combustion analysis and a data reconciliation algorithm. • Factors for the variance of the analysis results are statistically quantified. - Abstract: The biogenic fraction of a simple solid recovered fuel (SRF) mixture (80 wt% printer paper/20 wt% high density polyethylene) is analyzed with the in-house developed adapted balance method (aBM). This fairly new approach is a combination of combustion elemental analysis (CHNS) and a data reconciliation algorithm based on successive linearisation for evaluation of the analysis results. This method shows a great potential as an alternative way to determine the biomass content in SRF. However, the employed analytical technique (CHNS elemental analysis) restricts the probed sample mass to low amounts in the range of a few hundred milligrams. This requires sample comminution to small grain sizes (<200 μm) to generate representative SRF specimen. This is not easily accomplished for certain material mixtures (e.g. SRF with rubber content) by conventional means of sample size reduction. This paper presents a proof of principle investigation of the sample preparation and analysis of an SRF model mixture with the use of cryogenic impact milling (final sample comminution) and the adapted balance method (determination of biomass content). The so derived sample preparation methodology (cutting mills and cryogenic impact milling) shows a better performance in accuracy and precision for the determination of the biomass content than one solely based on cutting mills. The results for the determination of the biogenic fraction are within 1–5% of the data obtained by the reference methods, selective dissolution method (SDM) and {sup 14}C-method ({sup 14}C-M)

OSTI ID:
22436820
Journal Information:
Waste Management, Vol. 34, Issue 11; Other Information: Copyright (c) 2014 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.; Country of input: International Atomic Energy Agency (IAEA); ISSN 0956-053X
Country of Publication:
United States
Language:
English