Title: Patient feature based dosimetric Pareto front prediction in esophageal cancer radiotherapy

Journal Article · · Medical Physics
DOI:https://doi.org/10.1118/1.4906252· OSTI ID:22413408
; ; ; ; ; ;  [1];  [2];  [3]
  1. Department of Radiation Oncology, Fudan University Shanghai Cancer Center, Shanghai 200032, China and Department of Oncology, Shanghai Medical College, Fudan University, Shanghai 200032 (China)
  2. The 1st Affiliated Hospital of Wenzhou Medical College, Wenzhou, Zhejiang 325000 (China)
  3. Department of Radiation Oncology, University of Miami-Miller School of Medicine, Miami, Florida 33136 (United States)

Purpose: To investigate the feasibility of the dosimetric Pareto front (PF) prediction based on patient’s anatomic and dosimetric parameters for esophageal cancer patients. Methods: Eighty esophagus patients in the authors’ institution were enrolled in this study. A total of 2928 intensity-modulated radiotherapy plans were obtained and used to generate PF for each patient. On average, each patient had 36.6 plans. The anatomic and dosimetric features were extracted from these plans. The mean lung dose (MLD), mean heart dose (MHD), spinal cord max dose, and PTV homogeneity index were recorded for each plan. Principal component analysis was used to extract overlap volume histogram (OVH) features between PTV and other organs at risk. The full dataset was separated into two parts; a training dataset and a validation dataset. The prediction outcomes were the MHD and MLD. The spearman’s rank correlation coefficient was used to evaluate the correlation between the anatomical features and dosimetric features. The stepwise multiple regression method was used to fit the PF. The cross validation method was used to evaluate the model. Results: With 1000 repetitions, the mean prediction error of the MHD was 469 cGy. The most correlated factor was the first principal components of the OVH between heart and PTV and the overlap between heart and PTV in Z-axis. The mean prediction error of the MLD was 284 cGy. The most correlated factors were the first principal components of the OVH between heart and PTV and the overlap between lung and PTV in Z-axis. Conclusions: It is feasible to use patients’ anatomic and dosimetric features to generate a predicted Pareto front. Additional samples and further studies are required improve the prediction model.

OSTI ID:
22413408
Journal Information:
Medical Physics, Vol. 42, Issue 2; Other Information: (c) 2015 American Association of Physicists in Medicine; Country of input: International Atomic Energy Agency (IAEA); ISSN 0094-2405
Country of Publication:
United States
Language:
English