Title: Note: Effect of hot liner in producing {sup 40,48}Ca beam from RIKEN 18-GHz electron cyclotron resonance ion source

Journal Article · · Review of Scientific Instruments
DOI:https://doi.org/10.1063/1.4906595· OSTI ID:22392342
; ;  [1]
  1. Nishina Center for Accelerator Based Science, RIKEN, Wako, Saitama 351-0198 (Japan)

In order to produce a high-intensity and stable {sup 48}Ca beam from the RIKEN 18-GHz electron cyclotron resonance ion source, we have begun testing the production of a calcium beam using a micro-oven. To minimize the consumption rate of the material ({sup 48}Ca), we introduced the “hot liner” method and investigated the effect of the liner on the material consumption rate. The micro-oven was first used to produce the {sup 48}Ca beam for experiments in the RIKEN radioisotope beam factory, and a stable beam could be supplied for a long time with low consumption rate.

OSTI ID:
22392342
Journal Information:
Review of Scientific Instruments, Vol. 86, Issue 1; Other Information: (c) 2015 AIP Publishing LLC; Country of input: International Atomic Energy Agency (IAEA); ISSN 0034-6748
Country of Publication:
United States
Language:
English

Similar Records

Operational test of micro-oven for {sup 48}Ca beam
Journal Article · Sat Feb 15 00:00:00 EST 2014 · Review of Scientific Instruments · OSTI ID:22392342

Control system renewal for efficient operation in RIKEN 18 GHz electron cyclotron resonance ion source
Journal Article · Mon Feb 15 00:00:00 EST 2016 · Review of Scientific Instruments · OSTI ID:22392342

Recent development of RIKEN 28 GHz superconducting electron cyclotron resonance ion source
Journal Article · Sat Feb 15 00:00:00 EST 2014 · Review of Scientific Instruments · OSTI ID:22392342