Title: Experiment vs simulation RT WFNDEC 2014 benchmark: CIVA results

The French Atomic Energy Commission and Alternative Energies (CEA) has developed for years the CIVA software dedicated to simulation of NDE techniques such as Radiographic Testing (RT). RT modelling is achieved in CIVA using combination of a determinist approach based on ray tracing for transmission beam simulation and a Monte Carlo model for the scattered beam computation. Furthermore, CIVA includes various detectors models, in particular common x-ray films and a photostimulable phosphor plates. This communication presents the results obtained with the configurations proposed in the World Federation of NDEC 2014 RT modelling benchmark with the RT models implemented in the CIVA software.
Authors:
; ; ; ; ;  [1] ;  [2]
  1. CEA LIST, CEA Saclay 91191 Gif sur Yvette Cedex (France)
  2. Institut de Radioprotection et de Sûreté Nucléaire, B.P.17 92262 Fontenay-Aux-Roses (France)
Publication Date:
OSTI Identifier:
22391238
Resource Type:
Journal Article
Resource Relation:
Journal Name: AIP Conference Proceedings; Journal Volume: 1650; Journal Issue: 1; Conference: 41. Annual Review of Progress in Quantitative Nondestructive Evaluation, Boise, ID (United States), 20-25 Jul 2014; Other Information: (c) 2015 AIP Publishing LLC; Country of input: International Atomic Energy Agency (IAEA)
Country of Publication:
United States
Language:
English
Subject: