skip to main content

SciTech ConnectSciTech Connect

Title: SU-E-T-244: Motion Control Challenges in High Dose Rate Brachytherapy

Purpose: High dose rate (HDR) brachytherapy dose distribution is highly localized and has a very sharp fall-off. Thus the one of the most important part of the treatment is the localization and immobilization of the applicator from the implantation to the setup verification to the treatment delivery. The smallest motions of the patient can induce a small rotation, tilt, or translational movement of the applicator that can convert into miss of a significant part of the tumor or to over irradiating a nearby critical organ.The purpose of this study is to revise most of the HDR types of treatments with their applicators and their localization challenges. Since every millimeter of misplacement counts the study will look into the necessity of increasing the immobilization for several types of applicators. Methods: The study took over 136 plans generated by the treatment planning system (TPS) looking into the applicator placement in regard to the organs at risk (OR) and simulated the three possible displacements at the hottest dose point on the critical organ for several accessories to evaluate the variation of the delivered dose at the point due to the displacement. Results: Many of the present immobilization devices produced for external radiotherapy canmore » be used to improve the localization of HDR applicators during transportation of the patient and during treatment. Conclusion: This study data indicates that an improvement of the immobilization devices for HDR is absolutely necessary. Better applicator fixation devices are required too. Developing new immobilization devices for all the applicators is recommended.« less
Authors:
;  [1] ;  [2] ;  [3]
  1. Florida Atlantic University, Boca Raton, FL (United States)
  2. South Florida Radiation Oncology and Florida Atlantic University, Boca Raton, FL (United States)
  3. University of Bucharest, Bucharest-magurele, Ilfov (Romania)
Publication Date:
OSTI Identifier:
22351068
Resource Type:
Journal Article
Resource Relation:
Journal Name: Medical Physics; Journal Volume: 41; Journal Issue: 6; Other Information: (c) 2014 American Association of Physicists in Medicine; Country of input: International Atomic Energy Agency (IAEA)
Country of Publication:
United States
Language:
English
Subject:
60 APPLIED LIFE SCIENCES; BRACHYTHERAPY; DOSE RATES; NEOPLASMS; ORGANS; PATIENTS; RADIATION DOSE DISTRIBUTIONS; RADIATION DOSES