Title: SU-E-T-148: Efficient Verification Method for Modulated Electron Radiotherapy Treatment Plans

Purpose: For shallow tumors, modulated electron radiotherapy (MERT) promises a reduction of dose to distal organs at risk. At our institution a framework was developed in order to create treatment plans for MERT employing both forward and inverse optimization. In this work, an efficient quality assurance (QA) process is established. Methods: Treatment plans for three different tumor sites were created using an inverse optimization. These plans consist of 6–12 segments and energies between 6 and 18 MeV. An already established QA process for photon IMRT plans is now extended to additionally handle MERT plans. First, the dose distributions are calculated in a homogenous water phantom. For this task a dedicated Monte Carlo (MC) framework for MERT is used. Second, the segments are applied on a stand-alone amorphous silicon electronic portal imaging device (EPID) using a source-to-surface distance of 70 cm. This device was calibrated for electron beams in a previous work. An in-house developed analysis software, is then utilized for comparisons and evaluation of the measured and calculated dose distributions. Results: For all three plans the calculated dose distributions agree well with the measured ones. Using a 2D gamma comparison (2% of dose max/2 mm and 10% dose threshold) passingmore » rates >98% are achieved.The dose calculation for each plan on the water phantom, using voxels of 0.2×0.2×0.2 cm{sup 3}, takes at maximum 30 min on a single core Pentium 2.66 GHz system with 6 GB RAM, to reach a statistical uncertainty of 2% (1 std. dev.). Conclusion: An already established QA procedure for IMRT photon plans was applied for MERT. The dedicated MC framework and the use of EPID measurements allow an efficient QA procedure in a clinical environment. This work was supported by Varian Medical Systems.« less
Authors:
; ; ; ; ; ; ; ;  [1] ;  [2]
  1. of Medical Radiation Physics and Department of Radiation Oncology, Inselspital, Bern University Hospital, and University of Bern (Switzerland)
  2. Clinic for Radiation-Oncology, Lindenhofspital Bern (Switzerland)
Publication Date:
OSTI Identifier:
22339901
Resource Type:
Journal Article
Resource Relation:
Journal Name: Medical Physics; Journal Volume: 41; Journal Issue: 6; Other Information: (c) 2014 American Association of Physicists in Medicine; Country of input: International Atomic Energy Agency (IAEA)
Country of Publication:
United States
Language:
English
Subject:
60 APPLIED LIFE SCIENCES; COMPUTER CODES; ELECTRON BEAMS; MONTE CARLO METHOD; NEOPLASMS; OPTIMIZATION; PHANTOMS; PHOTONS; QUALITY ASSURANCE; RADIATION DOSE DISTRIBUTIONS; RADIATION DOSES; RADIOTHERAPY; VERIFICATION