Title: Measurement of axial injection displacement with trim coil current unbalance

The Dee probe used for measuring internal radial beam intensity shows large losses inside the radius of 20 cm of the 88 in. cyclotron. The current of the top and bottom innermost trim coil 1 is unbalanced to study effects of the axial injection displacement. A beam profile monitor images the ion beam bunches, turn by turn. The experimental bunch center of mass position is compared with calculations of the magnetic mirror effect displacement and shows good agreement.
Authors:
 [1]
  1. Lawrence Berkeley National Laboratory, 1 Cyclotron Road, Berkeley, California 94720 (United States)
Publication Date:
OSTI Identifier:
22314672
Resource Type:
Journal Article
Resource Relation:
Journal Name: Review of Scientific Instruments; Journal Volume: 85; Journal Issue: 8; Other Information: (c) 2014 AIP Publishing LLC; Country of input: International Atomic Energy Agency (IAEA)
Country of Publication:
United States
Language:
English
Subject:
46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY; BEAM BUNCHERS; BEAM INJECTION; BEAM PROFILES; COMPARATIVE EVALUATIONS; CURRENTS; CYCLOTRONS; ELECTRIC COILS; IMAGES; MAGNETIC MIRRORS; PROBES