Title: Tomographic image of prompt gamma ray from boron neutron capture therapy: A Monte Carlo simulation study

Purpose of paper is to confirm the feasibility of acquisition of three dimensional single photon emission computed tomography image from boron neutron capture therapy using Monte Carlo simulation. Prompt gamma ray (478 keV) was used to reconstruct image with ordered subsets expectation maximization method. From analysis of receiver operating characteristic curve, area under curve values of three boron regions were 0.738, 0.623, and 0.817. The differences between length of centers of two boron regions and distance of maximum count points were 0.3 cm, 1.6 cm, and 1.4 cm.
Authors:
; ;  [1] ;  [2]
  1. Department of Biomedical Engineering and Research Institute of Biomedical Engineering, College of Medicine, Catholic University of Korea, Seoul 505 (Korea, Republic of)
  2. Molecular Imaging Program at Stanford (MIPS), Department of Radiology, Stanford University, 300 Pasteur Drive, Stanford, California 94305 (United States)
Publication Date:
OSTI Identifier:
22293040
Resource Type:
Journal Article
Resource Relation:
Journal Name: Applied Physics Letters; Journal Volume: 104; Journal Issue: 8; Other Information: (c) 2014 AIP Publishing LLC; Country of input: International Atomic Energy Agency (IAEA)
Country of Publication:
United States
Language:
English
Subject:
62 RADIOLOGY AND NUCLEAR MEDICINE; 73 NUCLEAR PHYSICS AND RADIATION PHYSICS; BORON; COMPUTERIZED SIMULATION; IMAGES; MONTE CARLO METHOD; NEUTRON CAPTURE THERAPY; PROMPT GAMMA RADIATION; SINGLE PHOTON EMISSION COMPUTED TOMOGRAPHY; THREE-DIMENSIONAL CALCULATIONS