Title: Thermographic inspection of massive structures

Journal Article · · AIP Conference Proceedings
DOI:https://doi.org/10.1063/1.4864927· OSTI ID:22263839
; ;  [1]
  1. Electric Power Research Institute (EPRI), 3420 Hillview Avenue, Palo Alto, CA 94304 (United States)

Nondestructive Evaluation of concrete structures is a growing concern for the nuclear industry as well as for many other industries. As critical concrete components continue to age, the ability to assess the health and suitability for continued service has become a key consideration. In some cases, repair of these structures is difficult and expensive, while replacement is prohibitively expensive or, in some cases, not feasible. Therefore, the ability to inspect these key assets is a primary concern, especially in the nuclear industry. Due to the large size of containment buildings, cooling towers, and other large concrete assets, the ability to rapidly inspect for defects of concern is very desirable. Thermographic inspection appears to have the required ability to rapidly inspect large structures to ascertain the location and size of many of the defects of concern. This ability was demonstrated by performing a thermographic inspection of a large concrete dam in 2 days.

OSTI ID:
22263839
Journal Information:
AIP Conference Proceedings, Vol. 1581, Issue 1; Conference: 40. annual review of progress in quantitative nondestructive evaluation, Baltimore, MD (United States), 21-26 Jul 2013, 10. international conference on Barkhausen noise and micromagnetic testing, Baltimore, MD (United States), 21-26 Jul 2013; Other Information: (c) 2014 AIP Publishing LLC; Country of input: International Atomic Energy Agency (IAEA); ISSN 0094-243X
Country of Publication:
United States
Language:
English

Similar Records

Thermographic inspection of pipes, tanks, and containment liners
Journal Article · Tue Mar 31 00:00:00 EDT 2015 · AIP Conference Proceedings · OSTI ID:22263839

Guidelines to thermographic inspection of electrical installations
Conference · Sat Dec 31 00:00:00 EST 1994 · OSTI ID:22263839

Multimodal Nondestructive Dry Cask Basket Structure and Spent Fuel Evaluation
Technical Report · Tue Dec 18 00:00:00 EST 2018 · OSTI ID:22263839