Precision measurement of transverse velocity distribution of a strontium atomic beam
- CAS Key Laboratory of Time and Frequency Primary Standards, National Time Service Center, Xi'an 710600 (China)
- State Key Laboratory of Precision Spectroscopy, Department of Physics, East China Normal University, Shanghai 200062 (China)
We measure the transverse velocity distribution in a thermal Sr atomic beam precisely by velocity-selective saturated fluorescence spectroscopy. The use of an ultrastable laser system and the narrow intercombination transition line of Sr atoms mean that the resolution of the measured velocity can reach 0.13 m/s, corresponding to 90 μK in energy units. The experimental results are in very good agreement with the results of theoretical calculations. Based on the spectroscopic techniques used here, the absolute frequency of the intercombination transition of {sup 88}Sr is measured using an optical-frequency comb generator referenced to the SI second through an H maser, and is given as 434 829 121 318(10) kHz.
- OSTI ID:
- 22251224
- Journal Information:
- AIP Advances, Vol. 4, Issue 2; Other Information: (c) 2014 Author(s); Country of input: International Atomic Energy Agency (IAEA); ISSN 2158-3226
- Country of Publication:
- United States
- Language:
- English