Title: Construction and measurements of a vacuum-swing-adsorption radon-mitigation system

Journal Article · · AIP Conference Proceedings
DOI:https://doi.org/10.1063/1.4818089· OSTI ID:22224172
; ; ; ; ;  [1]
  1. Department of Physics, Syracuse University, Syracuse, NY 13244 (United States)

Long-lived alpha and beta emitters in the {sup 222}Rn decay chain on (and near) detector surfaces may be the limiting background in many experiments attempting to detect dark matter or neutrinoless double beta decay, and in screening detectors. In order to reduce backgrounds from radon-daughter plate-out onto the wires of the Beta Cage during its assembly, an ultra-low-radon cleanroom is being commissioned at Syracuse University using a vacuum-swing-adsorption radon-mitigation system. The radon filter shows ∼20× reduction at its output, from 7.47±0.56 to 0.37±0.12 Bq/m{sup 3}, and the cleanroom radon activity meets project requirements, with a lowest achieved value consistent with that of the filter, and levels consistently < 2 Bq/m{sup 3}.

OSTI ID:
22224172
Journal Information:
AIP Conference Proceedings, Vol. 1549, Issue 1; Conference: LRT 2013: 4. international workshop on low radioactivity techniques, Assergi (Italy), 10-12 Apr 2013; Other Information: (c) 2013 AIP Publishing LLC; Country of input: International Atomic Energy Agency (IAEA); ISSN 0094-243X
Country of Publication:
United States
Language:
English