Title: The energy transfer in the TEMP-4M pulsed ion beam accelerator

The results of a study of the energy transfer in the TEMP-4M pulsed ion beam accelerator are presented. The energy transfer efficiency in the Blumlein and a self-magnetically insulated ion diode was analyzed. Optimization of the design of the accelerator allows for 85% of energy transferred from Blumlein to the diode (including after-pulses), which indicates that the energy loss in Blumlein and spark gaps is insignificant and not exceeds 10%–12%. Most losses occur in the diode. The efficiency of energy supplied to the diode to the energy of accelerated ions is 8%–9% for a planar strip self-magnetic MID, 12%–15% for focusing diode and 20% for a spiral self-magnetic MID.
Authors:
; ;  [1]
  1. Tomsk Polytechnic University, 30 Lenin Ave., Tomsk 634050 (Russian Federation)
Publication Date:
OSTI Identifier:
22220540
Resource Type:
Journal Article
Resource Relation:
Journal Name: Review of Scientific Instruments; Journal Volume: 84; Journal Issue: 7; Other Information: (c) 2013 AIP Publishing LLC; Country of input: International Atomic Energy Agency (IAEA)
Country of Publication:
United States
Language:
English
Subject:
43 PARTICLE ACCELERATORS; ACCELERATORS; EFFICIENCY; ENERGY LOSSES; ENERGY TRANSFER; ION BEAMS; IONS; OPTIMIZATION; PLASMA GUNS; PULSES; SPARK GAPS; THERMIONIC DIODES