Title: Note: Characteristic beam parameter for the line electron gun

Journal Article · · Review of Scientific Instruments
DOI:https://doi.org/10.1063/1.4833777· OSTI ID:22220332
 [1];  [1]; ;  [2]
  1. Centre for High Energy Physics, University of the Punjab, Lahore 45590 (Pakistan)
  2. Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049 (China)

We have optimized the beam parameters of line source electron gun using Stanford Linear Accelerator Centre electron beam trajectory program (EGUN), utilizing electrostatic focusing only. We measured minimum beam diameter as 0.5 mm that corresponds to power density of 68.9 kW/cm{sup 2} at 13.5 mm in the post-anode region which is more than two-fold (33 kW/cm{sup 2}), of the previously reported results. The gun was operated for the validation of the theoretical results and found in good agreement. The gun is now without any magnetic and electrostatic focusing thus much simpler and more powerful.

OSTI ID:
22220332
Journal Information:
Review of Scientific Instruments, Vol. 84, Issue 11; Other Information: (c) 2013 AIP Publishing LLC; Country of input: International Atomic Energy Agency (IAEA); ISSN 0034-6748
Country of Publication:
United States
Language:
English

Similar Records

Note: Simulation and test of a strip source electron gun
Journal Article · Sun Jun 15 00:00:00 EDT 2014 · Review of Scientific Instruments · OSTI ID:22220332

Magnetically focused line source electron gun
Journal Article · Fri Oct 01 00:00:00 EDT 1982 · Rev. Sci. Instrum.; (United States) · OSTI ID:22220332

Design and performance of high uniformity linear filament electron gun
Journal Article · Sun Oct 15 00:00:00 EDT 2006 · Review of Scientific Instruments · OSTI ID:22220332